www.beisensors.com page 23/57
Object 1011h: Restore Parameters
This object is used to restore device and CANopen related parameters to factory settings.
Subindex Description Data Type Default Value Access Restore after
BootUp
0 Number of sub indices Unsigned 8 2 ro no
1 Restore all parameters Unsigned 32 “load” rw no
Storing procedure
To save the parameters to non volatile memory the access signature “load” has to be sent to the
corresponding subindex of the device.
Most significant word Least significant word
ASCII D a o l
Hex value 64h 61h 6Fh 6Ch
Note: The restoration of parameters will only be taken into account after a power up or reset command.
Please check all parameters before you store them to the non volatile memory.
Object 1012h: COB-ID Time Stamp Object
Th
is object contains the COB-ID of the Time Stamp object.
Subindex Description Data Type Default Value Access Restore after
BootUp
0 - Unsigned 32 100h rw no
Object 1013h: High Resolution Time Stamp
Th
is object contains a time stamp with a resolution of 1µs.
Subindex Description Data Type Default Value Access Restore after
BootUp
0 - Unsigned 32 0 rw no